Documented evidence for technical review
Report SZIN2306000944ML01_EN records a maximum force of 6,448 N for the submitted hanging-beam/P3.91 cabinet specimen at 5 mm/min. It is a destructive-test result, not a safe working-load rating.
This page helps buyers locate and interpret model-specific evidence. It is not a blanket statement that every product in a marketing series has the same certification or tested performance.
Document facts
| Reference | SZIN2306000944ML01_EN |
|---|---|
| Document date | 2023-06-13 |
| Models / specimens | Hanging beam and P3.91 finished cabinet; 500 × 500 mm; sample 001 |
| Standard / method | Customer-specified destructive tensile test; 5 mm/min |
| Printed expiry | Not stated here; absence of an expiry does not establish unlimited validity |
Scope and procurement checks
A destructive maximum-force result is not a safe working load (SWL), working load limit (WLL), approved hanging height or permitted mass above an audience. Rigging design requires the actual component combination, loading conditions, safety factors and a competent engineering review. Do not substitute the 6,448 N and 11,027 N results for one another.
Questions to settle before specification
Does this evidence apply to the quoted configuration?
Match the model designation, electrical configuration, relevant materials and document version to the actual equipment. Changes can require a new applicability review.
Is current certification status confirmed by this page?
No live issuer-status confirmation is represented here. Read the archived evidence with its conditions and confirm current status when it is needed for a tender or purchase.
What else does the project need?
Product test evidence does not replace installation design, local electrical or structural requirements, or the approvals required by the destination market.
Original documents and traceability
Read the complete documents, including conditions and annexes. The links below preserve the existing source files; this page does not alter or reissue them.
- Lifting-Beam-Load-Testing-Report-en.pdf — PDF pages 1, 2
- Supporting original PDF — Lifting-Beam-Load-Testing-Report-ch.pdf
Claim references: CS-CLM-011. Document-content review: 16 September 2026. This review is not a new laboratory test or an issuer-status verification.